Clean and dry all surfaces, before applying the RS-GEL-100. With a spray applicator or roller apply a 1/8 inch coat of the product to the paint surface only, cover with plastic to reduce evaporation. The stripping time will depend on the air temperature, preferably at 90 degrees F. A reaction should occur within 2 to 4 hours. Once coating has been removed, rinse thorougly with cold water.